Moisture
Moisture moves slowly, invisibly, and it is the failure mode that outlives everyone on the project.
Fig. 04 — Vapour through a build-upRaise interior humidity and watch the plane move outward
With interior humidity at 59 per cent and a moderately vapour-resistant inner layer, the condensation plane sits 47 per cent of the way through the build-up from the exterior face — inside the structural depth, where accumulated moisture would be a durability risk.
The position
Water vapour diffuses through materials along a pressure gradient. Somewhere inside the assembly the temperature falls low enough for that vapour to condense — and where that plane sits, relative to the layers, is a design decision whether or not anyone made it deliberately.
Vapour control, drying capacity and material selection are one problem. An assembly that cannot dry in at least one direction is a liability regardless of its U-value.
What we ask
- 01Where does the dew point fall inside this assembly, in winter?
- 02Can this build-up dry, and in which direction?
- 03Is the vapour control layer continuous, or is it a drawing convention?
- 04What does this detail look like after fifteen monsoons?
How we answer it
- 01Interstitial condensation assessment
- 02Vapour control strategy and layer sequencing
- 03Material permeability and drying-capacity review
- 04Junction and interface risk review